<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Boiler Inspection</title>
	<atom:link href="https://tandex.com.au/tag/boiler-inspection/feed/" rel="self" type="application/rss+xml" />
	<link>https://tandex.com.au</link>
	<description>International Water Treatment Specialist for Boilers and Cooling Tower Systems</description>
	<lastBuildDate>Sun, 28 Jun 2026 21:45:37 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	
	<item>
		<title>Prevent Damage And Save Energy With Regular Boiler Blowdown</title>
		<link>https://tandex.com.au/boilers/boiler-blowdown/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=boiler-blowdown</link>
					<comments>https://tandex.com.au/boilers/boiler-blowdown/#respond</comments>
		
		<dc:creator><![CDATA[Tandex]]></dc:creator>
		<pubDate>Sun, 30 Nov 2025 23:08:41 +0000</pubDate>
				<category><![CDATA[Boilers]]></category>
		<category><![CDATA[Blowdowns]]></category>
		<category><![CDATA[Boiler Inspection]]></category>
		<category><![CDATA[Cost Reduction]]></category>
		<category><![CDATA[Scale]]></category>
		<category><![CDATA[Steam Engine]]></category>
		<guid isPermaLink="false">https://tandex.com.au/?p=5213</guid>

					<description><![CDATA[Running a boiler may feel like a well-rehearsed routine, but the maintenance habit that truly makes the difference is regular boiler blowdown. It is not simply another checklist item. Nor is it something our technicians raise without good reason. Blowdown is the key to maintaining healthy boiler water, protecting your equipment, and keeping your system operating at peak…]]></description>
										<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background hundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:0px;--awb-padding-right:12%;--awb-padding-left:12%;--awb-padding-right-medium:6%;--awb-padding-left-medium:6%;--awb-padding-right-small:7%;--awb-padding-left-small:7%;--awb-margin-top:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-justify-content-space-between fusion-flex-content-wrap" style="width:calc( 100% + 30px ) !important;max-width:calc( 100% + 30px ) !important;margin-left: calc(-30px / 2 );margin-right: calc(-30px / 2 );"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column" style="--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:calc( 0.02 * calc( 100% - 30px ) );--awb-margin-bottom-large:30px;--awb-spacing-left-large:calc( 0.02 * calc( 100% - 30px ) );--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:calc( 0.02 * calc( 100% - 30px ) );--awb-spacing-left-medium:calc( 0.02 * calc( 100% - 30px ) );--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:calc( 0.02 * calc( 100% - 30px ) );--awb-spacing-left-small:calc( 0.02 * calc( 100% - 30px ) );"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column"><div class="fusion-title title fusion-title-1 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-one" style="--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;--awb-font-size:var(--awb-typography1-font-size);"><h1 class="fusion-title-heading title-heading-center fusion-responsive-typography-calculated" style="font-family:var(--awb-typography1-font-family);font-weight:var(--awb-typography1-font-weight);font-style:var(--awb-typography1-font-style);margin:0;letter-spacing:var(--awb-typography1-letter-spacing);text-transform:var(--awb-typography1-text-transform);font-size:1em;--fontSize:46;line-height:var(--awb-typography1-line-height);">Regular Boiler Blowdown: The Key to Efficiency, Longevity and Safety</h1></div><div class="fusion-text fusion-text-1" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-margin-top:30px;--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:500;"><p>Running a boiler may feel like a well-rehearsed routine, but the maintenance habit that truly makes the difference is regular boiler blowdown. It is not simply another checklist item. Nor is it something our technicians raise without good reason. Blowdown is the key to maintaining healthy boiler water, protecting your equipment, and keeping your system operating at peak performance within a <b><a href="https://tandex.com.au/boiler-water-treatment-solutions/" target="_blank" rel="noopener noreferrer">well-managed boiler water treatment program</a></b>.</p>
</div><div class="fusion-builder-row fusion-builder-row-inner fusion-row fusion-flex-align-items-stretch fusion-flex-justify-content-space-between fusion-flex-content-wrap" style="--awb-flex-grow:0;--awb-flex-grow-medium:0;--awb-flex-grow-small:0;--awb-flex-shrink:0;--awb-flex-shrink-medium:0;--awb-flex-shrink-small:0;width:calc( 100% + 30px ) !important;max-width:calc( 100% + 30px ) !important;margin-left: calc(-30px / 2 );margin-right: calc(-30px / 2 );"><div class="fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-0 fusion-flex-column fusion-flex-align-self-center" style="--awb-bg-size:cover;--awb-width-large:65%;--awb-margin-top-large:60px;--awb-spacing-right-large:15px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:15px;--awb-width-medium:65%;--awb-order-medium:0;--awb-margin-top-medium:60px;--awb-spacing-right-medium:15px;--awb-margin-bottom-medium:0px;--awb-spacing-left-medium:15px;--awb-width-small:100%;--awb-order-small:0;--awb-margin-top-small:60px;--awb-spacing-right-small:15px;--awb-spacing-left-small:15px;"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-center fusion-content-layout-row"><div class="fusion-text fusion-text-2" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:500;"><p>Every time water enters your boiler, it brings dissolved minerals and suspended solids, which is why proper feedwater <b><a href="https://tandex.com.au/water-pretreatment-and-filtration/" target="_blank" rel="noopener noreferrer">pre-treatment</a></b> and <b><a href="https://tandex.com.au/boilers/carbon-filter-in-water-treatment/" target="_blank" rel="noopener noreferrer">carbon filtration</a></b> can make such a difference to system performance. As the boiler generates steam, those impurities stay behind, slowly concentrating in the remaining water. As Total Dissolved Solids, or TDS, rise in the system over time, operational issues begin to emerge. <span style="letter-spacing: 0.24px; background-color: rgba(0, 0, 0, 0);">When TDS gets too high, scale starts to form on heat-transfer surfaces, sludge settles at the base of the boiler, and foaming or carry-over can push water into your steam line. That contamination affects steam quality, reduces efficiency, and can even impact your end product. In short, if you don’t control TDS, the boiler works harder, burns more fuel, and <b><a href="https://tandex.com.au/cooling-towers/cost-of-downtime/" target="_blank" rel="noopener noreferrer">risks unplanned downtime</a></b>.</span></p>
</div><div class="fusion-text fusion-text-3 fusion-no-small-visibility fusion-no-medium-visibility" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:500;"><p>That’s why boiler blowdown is so important. By releasing a small amount of water from the boiler, you remove those impurities before they cause damage. Although the process is straightforward, it plays a critical role in protecting your investment, improving fuel efficiency and extending the life of your system.</p>
</div></div></div><div class="fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-1 fusion-flex-column fusion-flex-align-self-center" style="--awb-bg-size:cover;--awb-width-large:35%;--awb-margin-top-large:30px;--awb-spacing-right-large:15px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:15px;--awb-width-medium:35%;--awb-order-medium:0;--awb-margin-top-medium:30px;--awb-spacing-right-medium:15px;--awb-spacing-left-medium:15px;--awb-width-small:100%;--awb-order-small:0;--awb-margin-top-small:-30px;--awb-spacing-right-small:calc( 0.15 * calc( 100% - 30px ) );--awb-margin-bottom-small:0px;--awb-spacing-left-small:calc( 0.15 * calc( 100% - 30px ) );"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-center fusion-content-layout-row"><div class="fusion-image-element" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-1 hover-type-none full-height-img" style="border-radius:40px;"><img fetchpriority="high" decoding="async" width="1024" height="768" alt="Close-up of flaked, black boiler scale held in a technician’s hand after being removed during a routine boiler inspection, showing heavy internal scaling and deposit build-up." title="Boiler scale removed during inspection" src="https://tandex.com.au/wp-content/uploads/P1000774.jpg" class="img-responsive wp-image-5640" srcset="https://tandex.com.au/wp-content/uploads/P1000774-200x150.jpg 200w, https://tandex.com.au/wp-content/uploads/P1000774-400x300.jpg 400w, https://tandex.com.au/wp-content/uploads/P1000774-600x450.jpg 600w, https://tandex.com.au/wp-content/uploads/P1000774-800x600.jpg 800w, https://tandex.com.au/wp-content/uploads/P1000774.jpg 1024w" sizes="(max-width: 640px) 100vw, 1024px" /></span></div></div></div></div><div class="fusion-text fusion-text-4 fusion-no-small-visibility fusion-no-large-visibility" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:500;"><p>That’s why boiler blowdown is so important. By releasing a small amount of water from the boiler, you remove those impurities before they cause damage. Although the process is straightforward, it plays a critical role in protecting your investment, improving fuel efficiency and extending the life of your system.</p>
</div><div class="fusion-text fusion-text-5 fusion-no-small-visibility fusion-no-large-visibility" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-margin-top:60px;--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:500;"><p>At Tandex, we typically recommend keeping boiler water within a target range of 1,500–1,800 ppm TDS, which helps maintain balance between water quality and efficiency. Regular blowdown, paired with the right <b><a href="https://tandex.com.au/boiler-water-treatment-solutions/" target="_blank" rel="noopener noreferrer">boiler treatment program</a></b>, is the most effective way to achieve this. A good treatment program reduces the rate at which solids accumulate, meaning you can blow down less often, saving both water and energy and contributing to <b><a href="https://tandex.com.au/water-treatment-cost-reduction/" target="_blank" rel="noopener noreferrer">long-term cost reduction</a></b> in water treatment systems.</p>
</div><div class="fusion-builder-row fusion-builder-row-inner fusion-row fusion-flex-align-items-stretch fusion-flex-justify-content-space-between fusion-flex-content-wrap" style="--awb-flex-grow:0;--awb-flex-grow-medium:0;--awb-flex-grow-small:0;--awb-flex-shrink:0;--awb-flex-shrink-medium:0;--awb-flex-shrink-small:0;width:calc( 100% + 30px ) !important;max-width:calc( 100% + 30px ) !important;margin-left: calc(-30px / 2 );margin-right: calc(-30px / 2 );"><div class="fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-2 fusion-flex-column fusion-flex-align-self-center" style="--awb-bg-size:cover;--awb-width-large:35%;--awb-margin-top-large:30px;--awb-spacing-right-large:15px;--awb-margin-bottom-large:30px;--awb-spacing-left-large:15px;--awb-width-medium:35%;--awb-order-medium:0;--awb-margin-top-medium:-30px;--awb-spacing-right-medium:15px;--awb-margin-bottom-medium:0px;--awb-spacing-left-medium:15px;--awb-width-small:100%;--awb-order-small:1;--awb-margin-top-small:-30px;--awb-spacing-right-small:calc( 0.15 * calc( 100% - 30px ) );--awb-spacing-left-small:calc( 0.15 * calc( 100% - 30px ) );"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-center fusion-content-layout-row fusion-flex-align-items-center"><div class="fusion-image-element" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-2 hover-type-none full-height-img" style="border-radius:40px;"><img decoding="async" width="640" height="480" alt="Large industrial boiler installed on a customer site, featuring a red burner assembly, control panel, circulation pumps, and overhead pipework with an access platform above the unit." title="Large industrial boiler installation" src="https://tandex.com.au/wp-content/uploads/photo-1.jpg" class="img-responsive wp-image-5644" srcset="https://tandex.com.au/wp-content/uploads/photo-1-200x150.jpg 200w, https://tandex.com.au/wp-content/uploads/photo-1-400x300.jpg 400w, https://tandex.com.au/wp-content/uploads/photo-1-600x450.jpg 600w, https://tandex.com.au/wp-content/uploads/photo-1.jpg 640w" sizes="(max-width: 640px) 100vw, 640px" /></span></div></div></div><div class="fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-3 fusion-flex-column fusion-flex-align-self-center" style="--awb-bg-size:cover;--awb-width-large:65%;--awb-margin-top-large:60px;--awb-spacing-right-large:15px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:15px;--awb-width-medium:65%;--awb-order-medium:0;--awb-margin-top-medium:0px;--awb-spacing-right-medium:15px;--awb-spacing-left-medium:15px;--awb-width-small:100%;--awb-order-small:0;--awb-margin-top-small:60px;--awb-spacing-right-small:15px;--awb-spacing-left-small:15px;"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-center fusion-content-layout-row fusion-flex-align-items-center"><div class="fusion-text fusion-text-6 fusion-no-medium-visibility" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:500;"><p>At Tandex, we typically recommend keeping boiler water within a target range of 1,500–1,800 ppm TDS, which helps maintain balance between water quality and efficiency. Regular blowdown, paired with the right <b><a href="https://tandex.com.au/boiler-water-treatment-solutions/" target="_blank" rel="noopener noreferrer">boiler treatment program</a></b>, is the most effective way to achieve this. A good treatment program reduces the rate at which solids accumulate, meaning you can blow down less often, saving both water and energy and contributing to <b><a href="https://tandex.com.au/water-treatment-cost-reduction/" target="_blank" rel="noopener noreferrer">long-term cost reduction</a></b> in water treatment systems.</p>
<p>You might also hear our technicians mention automatic boiler blowdown systems. These can be either conductivity-controlled (responding to TDS readings) or time-based (operating on a scheduled interval and duration set by a controller). Automatic systems remove guesswork from the process. They ensure blowdown occurs consistently and precisely, even as operating conditions vary. They’re particularly useful for multi-shift sites or systems with fluctuating steam loads.</p>
</div><div class="fusion-text fusion-text-7 fusion-no-small-visibility fusion-no-large-visibility" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:500;"><p>You might also hear our technicians mention automatic boiler blowdown systems. These can be either conductivity-controlled (responding to TDS readings) or time-based (operating on a scheduled interval and duration set by a controller). Automatic systems remove guesswork from the process. They ensure blowdown occurs consistently and precisely, even as operating conditions vary. They’re particularly useful for multi-shift sites or systems with fluctuating steam loads.</p>
</div></div></div></div><div class="fusion-text fusion-text-8" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-margin-top:60px;--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:500;"><p>When our team reminds you to complete your blowdowns, it is not nagging. It is genuine preventative care. Boiler blowdown isn’t about making work; it’s about <b><a href="https://tandex.com.au/water-treatment-provider/" target="_blank" rel="noopener noreferrer">keeping your system reliable, safe, and efficient for years to come</a></b>. <span style="letter-spacing: 0.24px; background-color: rgba(0, 0, 0, 0);">To put it simply:</span></p>
</div><div class="fusion-builder-row fusion-builder-row-inner fusion-row fusion-flex-align-items-stretch fusion-flex-justify-content-space-between fusion-flex-content-wrap" style="--awb-flex-grow:0;--awb-flex-grow-medium:0;--awb-flex-grow-small:0;--awb-flex-shrink:0;--awb-flex-shrink-medium:0;--awb-flex-shrink-small:0;width:calc( 100% + 30px ) !important;max-width:calc( 100% + 30px ) !important;margin-left: calc(-30px / 2 );margin-right: calc(-30px / 2 );"><div class="fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-4 fusion_builder_column_inner_1_4 1_4 fusion-flex-column fusion-flex-align-self-stretch fusion-column-inner-bg-wrapper fusion-column-liftup-border" style="--awb-padding-top:20px;--awb-padding-right:15px;--awb-padding-left:15px;--awb-overflow:hidden;--awb-inner-bg-size:cover;--awb-border-color:var(--awb-color7);--awb-inner-border-color:var(--awb-color7);--awb-border-top:7px;--awb-inner-border-top:7px;--awb-border-right:7px;--awb-inner-border-right:7px;--awb-border-bottom:7px;--awb-inner-border-bottom:7px;--awb-border-left:7px;--awb-inner-border-left:7px;--awb-border-style:solid;--awb-inner-border-style:solid;--awb-border-radius:40px 40px 40px 40px;--awb-liftup-border-radius:40px 40px 40px 40px;--awb-width-large:25%;--awb-margin-top-large:0px;--awb-spacing-right-large:15px;--awb-margin-bottom-large:20px;--awb-spacing-left-large:15px;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:15px;--awb-spacing-left-medium:15px;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:15px;--awb-spacing-left-small:15px;"><span class="fusion-column-inner-bg hover-type-liftup"><span class="fusion-column-anchor"><span class="fusion-column-inner-bg-image"></span></span></span><div class="fusion-column-wrapper fusion-flex-justify-content-center fusion-content-layout-row fusion-flex-align-items-center"><div class="fusion-text fusion-text-9" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-text-color:var(--awb-color7);--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:700;"><p style="text-align: center;">Regular boiler blowdown prevents scale, sludge, and carry-over.</p>
</div></div></div><div class="fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-5 fusion_builder_column_inner_1_4 1_4 fusion-flex-column fusion-flex-align-self-stretch fusion-column-inner-bg-wrapper fusion-column-liftup-border" style="--awb-padding-top:20px;--awb-padding-right:15px;--awb-padding-left:15px;--awb-overflow:hidden;--awb-inner-bg-size:cover;--awb-border-color:var(--awb-color7);--awb-inner-border-color:var(--awb-color7);--awb-border-top:7px;--awb-inner-border-top:7px;--awb-border-right:7px;--awb-inner-border-right:7px;--awb-border-bottom:7px;--awb-inner-border-bottom:7px;--awb-border-left:7px;--awb-inner-border-left:7px;--awb-border-style:solid;--awb-inner-border-style:solid;--awb-border-radius:40px 40px 40px 40px;--awb-liftup-border-radius:40px 40px 40px 40px;--awb-width-large:25%;--awb-margin-top-large:0px;--awb-spacing-right-large:15px;--awb-margin-bottom-large:20px;--awb-spacing-left-large:15px;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:15px;--awb-spacing-left-medium:15px;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:15px;--awb-spacing-left-small:15px;"><span class="fusion-column-inner-bg hover-type-liftup"><span class="fusion-column-anchor"><span class="fusion-column-inner-bg-image"></span></span></span><div class="fusion-column-wrapper fusion-flex-justify-content-center fusion-content-layout-row fusion-flex-align-items-center"><div class="fusion-text fusion-text-10" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-text-color:var(--awb-color7);--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:700;"><p style="text-align: center;">Keeping TDS between 1,500–1,800 ppm protects both efficiency and equipment.</p>
</div></div></div><div class="fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-6 fusion_builder_column_inner_1_4 1_4 fusion-flex-column fusion-flex-align-self-stretch fusion-column-inner-bg-wrapper fusion-column-liftup-border" style="--awb-padding-top:20px;--awb-padding-right:15px;--awb-padding-left:15px;--awb-overflow:hidden;--awb-inner-bg-size:cover;--awb-border-color:var(--awb-color7);--awb-inner-border-color:var(--awb-color7);--awb-border-top:7px;--awb-inner-border-top:7px;--awb-border-right:7px;--awb-inner-border-right:7px;--awb-border-bottom:7px;--awb-inner-border-bottom:7px;--awb-border-left:7px;--awb-inner-border-left:7px;--awb-border-style:solid;--awb-inner-border-style:solid;--awb-border-radius:40px 40px 40px 40px;--awb-liftup-border-radius:40px 40px 40px 40px;--awb-width-large:25%;--awb-margin-top-large:0px;--awb-spacing-right-large:15px;--awb-margin-bottom-large:20px;--awb-spacing-left-large:15px;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:15px;--awb-spacing-left-medium:15px;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:15px;--awb-spacing-left-small:15px;"><span class="fusion-column-inner-bg hover-type-liftup"><span class="fusion-column-anchor"><span class="fusion-column-inner-bg-image"></span></span></span><div class="fusion-column-wrapper fusion-flex-justify-content-center fusion-content-layout-row fusion-flex-align-items-center"><div class="fusion-text fusion-text-11" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-text-color:var(--awb-color7);--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:700;"><p style="text-align: center;">The better your feedwater and treatment, the less blowdown you’ll need.</p>
</div></div></div><div class="fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-7 fusion_builder_column_inner_1_4 1_4 fusion-flex-column fusion-flex-align-self-stretch fusion-column-inner-bg-wrapper fusion-column-liftup-border" style="--awb-padding-top:20px;--awb-padding-right:15px;--awb-padding-left:15px;--awb-overflow:hidden;--awb-inner-bg-size:cover;--awb-border-color:var(--awb-color7);--awb-inner-border-color:var(--awb-color7);--awb-border-top:7px;--awb-inner-border-top:7px;--awb-border-right:7px;--awb-inner-border-right:7px;--awb-border-bottom:7px;--awb-inner-border-bottom:7px;--awb-border-left:7px;--awb-inner-border-left:7px;--awb-border-style:solid;--awb-inner-border-style:solid;--awb-border-radius:40px 40px 40px 40px;--awb-liftup-border-radius:40px 40px 40px 40px;--awb-width-large:25%;--awb-margin-top-large:0px;--awb-spacing-right-large:15px;--awb-margin-bottom-large:20px;--awb-spacing-left-large:15px;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:15px;--awb-spacing-left-medium:15px;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:15px;--awb-spacing-left-small:15px;"><span class="fusion-column-inner-bg hover-type-liftup"><span class="fusion-column-anchor"><span class="fusion-column-inner-bg-image"></span></span></span><div class="fusion-column-wrapper fusion-flex-justify-content-center fusion-content-layout-row fusion-flex-align-items-center"><div class="fusion-text fusion-text-12" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-text-color:var(--awb-color7);--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:700;"><p style="text-align: center;">Automatic systems can maintain consistent results and reduce waste.</p>
</div></div></div></div><div class="fusion-text fusion-text-13" style="--awb-font-size:var(--awb-typography4-font-size);--awb-line-height:var(--awb-typography4-line-height);--awb-letter-spacing:var(--awb-typography4-letter-spacing);--awb-text-transform:var(--awb-typography4-text-transform);--awb-margin-top:60px;--awb-text-font-family:&quot;Nunito Sans&quot;;--awb-text-font-style:normal;--awb-text-font-weight:500;"><p>If you’d like help reviewing your blowdown routine or understanding whether an automatic system would suit your site, our team can help. Visit our <b><a href="https://tandex.com.au/boiler-water-treatment-solutions/" target="_blank" rel="noopener noreferrer">Boiler Solutions</a></b> page for more information or <b><a href="https://tandex.com.au/contact-tandex/" target="_blank" rel="noopener noreferrer">contact us</a></b> to speak directly with a Tandex technician.</p>
</div></div></div></div></div>The post <a href="https://tandex.com.au/boilers/boiler-blowdown/">Prevent Damage And Save Energy With Regular Boiler Blowdown</a> first appeared on <a href="https://tandex.com.au">Tandex</a>.]]></content:encoded>
					